Scientific American Supplement, No. 561, October 2, 1886 by Various
page 19 of 163 (11%)
page 19 of 163 (11%)
|
At the fifth round the breech block opened with some difficulty, and
an examination showed that the resistance resulted from the diametral enlargement of the rear plate. Directions have been given to correct this defect. The star gauge records show that no material change took place in the diameter of the chamber or the bore. From 30 inches to 54 inches (measured from base of the breech), there was a diminution in diameter of from 0.001 in. to 0.002 in.; in rear of 30 inches there was no change. No enlargement in the shot chamber exceeded 0.001 in. From the bottom of the bore (the beginning of the rifling) to the muzzle the average enlargements were as follows: in. to 6 in., 0.005 in.; 7 in. to 14 in., 0.003 in.; 15 in. to 29 in., 0.002 in.; 30 in. to muzzle, 0.002 to 0.001 in. After the third round the joint between the D. and D. rings opened slightly on the top, and measured after the 13th round showed that the opening was about 0.004 in. wide. It cannot at present be stated whether or not this opening increased during firing, but the defect has been noted and will be carefully observed. Enough cocoa powder remains to allow a comparison to be made with such brown prismatic powder as may be adopted finally. No firing has been done as yet to test the best position for the bands, but it will take place as soon as enough of some standard powder is obtained to fire ten consecutive rounds.--_Army and Navy Journal._ * * * * * COMBUSTION, FIRE-BOXES, AND STEAM BOILERS.[1] |
|