the standard solution at once and finish the titration as prescribed
above, making use of the ferrous solution if the end-point should be passed. From the corrected volumes of the bichromate solution required to oxidize the iron actually know to be present in the wire, calculate the relation of the standard solution to the normal. Repeat the standardization until the results are concordant within at least two parts in one thousand. [Note 1: The hydrochloric acid is added to the ferrous solution to insure the presence of at least sufficient free acid for the titration, as required by the equation on page 48. The solution of the wire in hot acid and the short boiling insure the removal of compounds of hydrogen and carbon which are formed from the small amount of carbon in the iron. These might be acted upon by the bichromate if not expelled.] [Note 2: It is plain that all the iron must be reduced to the ferrous condition before the titration begins, as some oxidation may have occurred from the oxygen of the air during solution. It is also evident that any excess of the agent used to reduce the iron must be removed; otherwise it will react with the bichromate added later. The reagents available for the reduction of iron are stannous chloride, sulphurous acid, sulphureted hydrogen, and zinc; of these stannous chloride acts most readily, the completion of the reaction |
|