the standard solution at once and finish the titration as prescribed
above, making use of the ferrous solution if the end-point should be
passed.

From the corrected volumes of the bichromate solution required to
oxidize the iron actually know to be present in the wire, calculate
the relation of the standard solution to the normal.

Repeat the standardization until the results are concordant within at
least two parts in one thousand.


[Note 1: The hydrochloric acid is added to the ferrous solution
to insure the presence of at least sufficient free acid for the
titration, as required by the equation on page 48.

The solution of the wire in hot acid and the short boiling insure the
removal of compounds of hydrogen and carbon which are formed from the
small amount of carbon in the iron. These might be acted upon by the
bichromate if not expelled.]

[Note 2: It is plain that all the iron must be reduced to the ferrous
condition before the titration begins, as some oxidation may have
occurred from the oxygen of the air during solution. It is also
evident that any excess of the agent used to reduce the iron must be
removed; otherwise it will react with the bichromate added later.

The reagents available for the reduction of iron are stannous
chloride, sulphurous acid, sulphureted hydrogen, and zinc; of these
stannous chloride acts most readily, the completion of the reaction