The Water Supply of the El Paso and Southwestern Railway from Carrizozo to Santa Rosa, N. Mex. - American Society of Civil Engineers: Transactions, No. 1170 by J. L. Campbell
page 24 of 38 (63%)
page 24 of 38 (63%)
![]() | ![]() |
|
" " 16 " " = 47,500 "
Time, = 13,800 sec. Let _x_ = velocity of flow in 16-in. pipe, in feet per second, then 2.56 _x_ = velocity of flow in 10-in. pipe, in feet per second. From which: 13,200 47,500 ------- + ------- = 13,800 2.56_x_ _x_ _x_ = 3.805 and 2.56_x_ = 9.740 The discharge is: For the 16-in. pipe, 1.396 x 3.805 = 5.31 cu. ft. per sec.; and, for the 10-in. pipe, 0.5454 x 9.74 = 5.31 cu. ft. per sec. The question arose as to whether or not the particles of bran in the water traveled as fast as the water flowed. It was also desired to check by observation the relative velocities in the two pipes, as above deduced. |
|