19 |36,000|2.07|0.84|1.90|0.84|0.840||
20 |38,000|2.13|0.90|1.97|0.91|0.915|| 21 |40,000|2.20|0.97|2.03|0.97|0.970|| 22 |42,000|2.27|1.04|2.11|1.05|1.045|| 23 |44,000|2.37|1.14|2.21|1.15|1.145|| || 39,100 lb. First Crack; ||22,000 lb. First Crack; 45,130 lb. Failed. ||35,190 lb. Failed. || At Elastic Limit: Load, 24,000 lb.; ||At Elastic Limit: Load, 21,000 lb.; deflection, 0.535 in.; || deflection, 0.515 in.; _S_ 3,608 lb. || _S_, 3,054 lb. || Maximum: Load, 45,130 lb.; ||Maximum: Load, 35,190 lb.; deflection,.....; || deflection,.....; _S_ 6,785 lb. || _S_ 5,120 lb. || _E_ = 1,489,000 lb. || _E_ = 1,288,000 lb. ========================================================================== TABLE 4.--(_Continued._)--LOAD AND DEFLECTION LOG. BEAM IV. Columns in table: A: Load, in pounds. B: Reading. C: Total deflection. D: Mean total deflection. |
|